* Prices are valid between 01.01.2024 and 31.12.2024. 20% VAT is not included.
Analysis Code | Analysis Name | Explanation | Price |
---|---|---|---|
10-01-01 | TEM Analysis | The device is not available for use | |
10-02-01 | SEM Analysis | An average of 6 samples can be investigated in 1 hour. The samples should not contain moisture/oil. | 1250 TL/hr |
10-02-02 | EDX Analysis | An average of 6 samples can be investigated in 1 hour. The samples should not contain moisture/oil. | 1500 TL/hr |
10-02-03 | STEM Analysis | An average of 2 samples can be investigated in 1 hour. The samples should not contain moisture/oil and should be prepared on TEM grid. | 2000 TL/hr |
10-02-04 | ESEM Analysis | An average of 3 samples can be investigated in 1 hour. | 2000 TL/hr |
10-02-05 | WETSTEM Analysis | Please make an appointment for SEM2 machine only Wednesday. You should contact the lecturer for sample suitability. | 3500 TL/hr |
10-02-06 | SEM - User | People who have taken SEM training and have been granted a right to use it can make an online appointment. | 300 TL/hr |
10-03-01 | AFM Analysis | The sample size should be maximum 1 cm X 1 cm X 0.5 cm. The sample should not contain moisture/oil. Powder sample cannot be analyzed. | 1500 TL/hr |
10-03-02 | Fulid Cell | The sample should be maximum 1 cm X 1 cm X 0.5 cm. The sample must be fixed to the surface. The sample should not contain moisture/oil. Powder sample cannot be analyzed. | 2000 TL/hr |
10-03-03 | Peak Force QNM | The sample size should be maximum 1 cm X 1 cm X 0.5 cm. The sample should not contain moisture/oil. Powder sample cannot be analyzed. | 3500 TL/hr |
10-03-04 | Indentation | The sample size should be maximum 1 cm X 1 cm X 0.5 cm. The sample should not contain moisture/oil. Powder sample cannot be analyzed. | 3500 TL/hr |
10-04-01 | STM | The sample size should be maximum 1 cm X 1 cm X 0.5 cm. The sample should not contain moisture/oil. Samples must be conductive. Powder sample cannot be analyzed. | 3500 TL/hr |
10-11-01 | EDXRF | The sample should be at least 1 g. Particle size should be less than 100 microns. (If it is not in the desired size, the grinding option should be selected) Solid samples 32 mm or 40 mm diameter, maximum 10 mm height should be. When Fusion is desired, "Loss of Ignition" and "Fusion" pre-preparation processes should be selected. When the necessary preparation procedures are not selected, additions will be made by the expert. | 500 TL/piece |
10-12-01 | XRD Fast Scan Analysis (Standard), 0.08 ∘∕s , ∼17min | The amount of the sample must be the 1/4 of an eppendorf tube. Sample must be in fine powder form (100µ >). Scan range must be specified in the request form. | 500 TL/piece |
10-12-02 | XRD MediumScan Analysis (Standard), 0.04 ∘∕s, ∼ 33min | The amount of the sample must be the 1/4 of an eppendorf tube. Sample must be in fine powder form (100µ >) Scan range must be specified in the request form. | 600 TL/piece |
10-12-03 | XRD Low Scan Analysis (Standard), 0.02 ∘∕s, ∼65min | The amount of the sample must be the 1/4 of an eppendorf tube. Sample must be in fine powder form (100µ >) Scan range must be specified in the request form. | 700 TL/piece |
10-12-04 | Crystal Structure Analysis | XRD Analysis must have been acquired in IYTE CMR | 600 TL/hr |
10-14-01 | Spectrofluorometer (Solid Samples) | Laser Sources for LifeTime Measurements: EPLED - 300 ± 10 nm; EPL - 450 ± 10 nm; EPLED - 560 ± 10 nm Solid samples should be prepared as thin films. | 350 TL/hr |
10-14-02 | Spectrofluorometer (Liquid Samples) | Laser Sources for LifeTime Measurements: EPLED - 300 ± 10 nm; EPL - 450 ± 10 nm; EPLED - 560 ± 10 nm Amount of sample should be at least 100 μL. Liquid samples should be sent with their solvent. Samples should be sent with cuvettes. For Quantum Yield measurements, screw cap cuvettes are required. | 350 TL/hr |
10-15-01 | RAMAN - Single Spectrum | Laser Sources: 532nm, ve 785nm Objectives: x5, x20, x50, x100 Solid, Liquid, Powder and thin film samples Sample diameters sould be 4cmx8cmx2cm | 750 TL/piece |
10-15-02 | RAMAN - Multiple Spectrum | Laser Sources: 532nm, ve 785nm Objectives: x5, x20, x50, x100 Solid, Liquid, Powder and thin film samples Sample diameters sould be 4cmx8cmx2cm | 1750 TL/piece |
10-15-03 | RAMAN - Depth Profile | Laser Sources: 532nm, ve 785nm Objectives: x5, x20, x50, x100 Solid, Liquid, Powder and thin film samples Sample diameters sould be 4cmx8cmx2cm | 1850 TL/piece |
10-15-04 | RAMAN - 2D Mapping | Laser Sources: 532nm, ve 785nm Objectives: x5, x20, x50, x100 Solid, Liquid, Powder and thin film samples Sample diameters sould be 4cmx8cmx2cm | 2500 TL/hr |
10-21-01 | TGA Analysis - 1 hour | Sample amount should be between 3-10 mg. | 500 TL/piece |
10-21-02 | TGA Analysis - 2 hours | Sample amount should be between 3-10 mg. The device reaches a maximum of 1200 °C. | 600 TL/piece |
10-21-03 | TGA Analysis - 3 hours | Sample amount should be between 3-10 mg. The device reaches a maximum of 1200 °C. | 800 TL/piece |
10-21-04 | TGA Analysis - 4 hours | Sample amount should be between 3-10 mg. The device reaches a maximum of 1200 °C. | 1000 TL/piece |
10-22-01 | DSC Analysis- 1 hour | Sample amount should be between 3-10 mg. The device works between -40 °C and 350 °C. | 500 TL/piece |
10-22-02 | DSC Analysis-2 hours | Sample amount should be between 3-10 mg. The device works between -40 °C and 350 °C. | 600 TL/piece |
10-22-03 | DSC Analysis-3 hours | Sample amount should be between 3-10 mg. The device works between -40 °C and 350 °C. | 800 TL/piece |
10-22-04 | DSC Analysis-4 hours | Sample amount should be between 3-10 mg. The device works between -40 °C and 350 °C. | 1000 TL/piece |
10-23-01 | Dilatometer | The device reaches a maximum of 1200 °C. Please contact the specialist to specify the size of your sample. | 800 TL/piece |
10-31-01 | BET Analysis | Sample amount should be at least 300 mg. Degas conditions must be specified. | 750 TL/piece |
10-31-02 | BET (Adsorption/Desorption) | Sample amount should be at least 300 mg. Degas conditions must be specified. | 1000 TL/piece |
10-32-01 | Tensile | The thickness of the samples should be 8 mm maximum. The lecturer should be contacted. | 500 TL/piece |
10-32-02 | Compression | The lecturer should be contacted. | 500 TL/piece |
10-32-03 | High Temperature Tensile Testing | The lecturer should be contacted. | 1500 TL/piece |
10-33-01 | Lecturer Report | It is prepared by the lecturer who is the expert of the device. | 2000 TL/piece |
10-33-02 | Faculty Member Report | It is prepared by member of teaching of IZTECH | 4000 TL/piece |
Coating | Au coating for SEM sample preparation | 100 TL/piece | |
XRF Fusion | Sample preparation for XRF analysis | 200 TL/piece | |
Milling | Sample preparation for XRF and XRD analysis | 150 TL/piece | |
Loss of Ignition | Sample preparation for XRF analysis | 200 TL/piece |