• Language
    • Türkçe
    • English
Malzeme Araştırma Merkezi
  • Home
  • About Us
    • About Us
    • Purpose of the Center
    • Regulation of the Centre
    • People
    • Board of Directors
  • Equipment
    • AFM
    • BET
    • DILATOMETER
    • FS5
    • MTM
    • SEM
    • TGA
    • XRD
    • XRF
  • Analysis/Proforma Invoice Requests
    • Analysis Price List
    • Analysis Request (EAS-e-TAM)
  • Other
  • Contact Us
  • IRC Homepage

Analysis Price List

You are here:Home » Analysis Price List
Analysis CodeAnalysis NameExplanationPrice
10-01-01TEM AnalysisThe device is not available for use
10-02-01SEM Analysis An average of 6 samples can be investigated in 1 hour.
The samples should not contain moisture/oil.
Please make an appointment for SEM (https://mamrandevu.iyte.edu.tr/).
360TL/hr
10-02-02EDX AnalysisAn average of 6 samples can be investigated in 1 hour.
The samples should not contain moisture/oil.
Please make an appointment for SEM-EDX (https://mamrandevu.iyte.edu.tr/).
432TL/hr
10-02-03STEM AnalysisAn average of 2 samples can be investigated in 1 hour.
The samples should not contain moisture/oil and should be prepared on TEM grid.
Please make an appointment for SEM-STEM (https://mamrandevu.iyte.edu.tr/).
576 TL/hr
10-02-04ESEM AnalysisAn average of 3 samples can be investigated in 1 hour.
Please make an appointment for SEM-ESEM (https://mamrandevu.iyte.edu.tr/).
576 TL/hr
10-02-05WETSTEM AnalysisPlease make an appointment for SEM2 machine only Wednesday.
You should contact the lecturer for sample suitability (https://mamrandevu.iyte.edu.tr/).
720 TL/hr
10-02-06SEM - UserPeople who have taken SEM training and have been granted a right to use it can make an online appointment.72 TL/hr
10-03-01AFM AnalysisThe sample size should be maximum 1 cm X 1 cm X 0.5 cm.
The sample should not contain moisture/oil.
Powder sample cannot be analyzed.
Please make an appointment (https://mamrandevu.iyte.edu.tr/).
504 TL/hr
10-03-02Fulid CellThe sample should be maximum 1 cm X 1 cm X 0.5 cm.
The sample must be fixed to the surface.
The sample should not contain moisture/oil.
Powder sample cannot be analyzed
Please make an appointment (https://mamrandevu.iyte.edu.tr/).
720 TL/hr
10-03-03Peak Force QNMThe sample size should be maximum 1 cm X 1 cm X 0.5 cm.
The sample should not contain moisture/oil.
Powder sample cannot be analyzed.
Please make an appointment (https://mamrandevu.iyte.edu.tr/).
1440 TL/hr
10-03-04IndentationThe sample size should be maximum 1 cm X 1 cm X 0.5 cm.
The sample should not contain moisture/oil.
Powder sample cannot be analyzed
Please make an appointment (https://mamrandevu.iyte.edu.tr/).
1440 TL/hr
10-04-01STM The sample size should be maximum 1 cm X 1 cm X 0.5 cm.
The sample should not contain moisture/oil.
Samples must be conductive.
Powder sample cannot be analyzed.
Please make an appointment (https://mamrandevu.iyte.edu.tr/).
1440 TL/hr
10-11-01XRF The sample should be at least 1 g.
Particle size should be less than 100 microns. (If it is not in the desired size, the grinding option should be selected)
Solid samples 32 mm or 40 mm diameter, maximum 10 mm height should be.
When Fusion is desired, "Loss of Ignition" and "Fusion" pre-preparation processes should be selected.
When the necessary preparation procedures are not selected, additions will be made by the expert.
180 TL/piece
10-12-01XRD Fast Scan Analysis (Standard), 0.08 ∘∕s , ∼17minThe amount of the sample must be the 1/4 of an eppendorf tube.
Sample must be in fine powder form (100µ >).
Scan range must be specified in the request form.
144 TL/piece
10-12-02XRD MediumScan Analysis (Standard), 0.04 ∘∕s, ∼ 33minThe amount of the sample must be the 1/4 of an eppendorf tube.
Sample must be in fine powder form (100µ >)
Scan range must be specified in the request form.
168 TL/piece
10-12-03XRD Low Scan Analysis (Standard), 0.02 ∘∕s, ∼65minThe amount of the sample must be the 1/4 of an eppendorf tube.
Sample must be in fine powder form (100µ >)
Scan range must be specified in the request form.
216 TL/piece
10-12-04Crystal Structure AnalysisXRD Analysis must have been acquired in IYTE CMR168 TL/piece
10-14-01Spectrofluorometer (Solid Samples)Laser Sources for LifeTime Measurements: EPLED - 300 ± 10 nm; EPL - 450 ± 10 nm; EPLED - 560 ± 10 nm
Solid samples should be prepared as thin films.
144 TL/hr
10-14-02Spectrofluorometer (Liquid Samples)Laser Sources for LifeTime Measurements: EPLED - 300 ± 10 nm; EPL - 450 ± 10 nm; EPLED - 560 ± 10 nm
Amount of sample should be at least 100 μL.
Liquid samples should be sent with their solvent.
Samples should be sent with cuvettes.
144 TL/hr
10-15-01SEDIGRAPH
(Analysis of Particle Size and Distribution Machine)
The sample should be at least 100 g.
The solid and colloids, emulsion, dry powder and powder mass samples in a liquid with known proporties can be analyzed.
288 TL/piece
10-21-01TGA Analysis - up to 800 ° C, 80 minSample amount should be between 10-20 mg. The device reaches a maximum of 800 °C.288 TL/piece
10-21-02TGA - up to 800 ° C,after 80 minSample amount should be between 10-20 mg. The device reaches a maximum of 800 °C.360 TL/piece
10-21-03TGA Analysis - up to 1200 ° C, 120 minSample amount should be between 10-20 mg. The device reaches a maximum of 1200 °C.360 TL/piece
10-21-04TGA Analysis - up to 1200 ° C, after 120 minSample amount should be between 10-20 mg. The device reaches a maximum of 1200 °C.432 TL/piece
10-22-01DSC AnalysisSample amount should be between 5-10 mg. The device works between -40 °C and 350 °C.288TL/piece
10-23-01DilatometerThe sample should have a maximum diameter of 5 mm and a height of 10-20 mm.240TL/piece
10-31-01BET AnalysisSample amount should be at least 300 mg. Degas conditions must be specified.336TL/piece
10-31-02BET (Adsorption/Desorption)Sample amount should be at least 300 mg. Degas conditions must be specified.504TL/piece
10-32-01TensileThe thickness of the samples should be 8 mm maximum. The lecturer should be contacted.216TL/piece
10-32-02CompressionThe lecturer should be contacted.216TL/piece
10-32-03High Temperature Tensile TestingThe lecturer should be contacted.432TL/piece
10-33-01Lecturer ReportIt is prepared by the lecturer who is the expert of the device.720TL/piece
10-33-02Faculty Member ReportIt is prepared by member of teaching of IZTECH1440TL/piece
Coating24 TL/piece
XRF Fusion72TL/piece
Milling60TL/piece
Loss of Ignition72TL/piece
back up
© Copyright 2023 Malzeme Araştırma Merkezi
  • Language
    • Türkçe
    • English